Bridges and viaducts

“Biennial inspections of the bridge over the Porto Salvo stream adjacent to Bairro da Tapada do Mocho – Paço de Arcos”
 
back
 
 
General view of the bridge  
Inspections and tests “in-situ”
           
 
Visual Inspection – Survey anomalies – Crack  
Survey anomalies – Crack opening measurement
           
 
Tests “in-situ” – Detection and evaluation of reinforcement cover with the covermeter  
Tests “in-situ” – Evaluating the depth of concrete carbonation - Spraying with alcoholic solution of phenolphthalein
           
 
Tests “in-situ” – Evaluating the depth of concrete carbonation  
Evaluating the concrete’s current resistance – Core drilling
           